ApexDeco
Plan
Settings
Tools
Help
Bottom Mix & Travel
+ Add Level
Delete
Deco Mixes
+ Add Deco
Delete
Bailout Mixes
+ Add Bailout
Delete
Previous Plans
Clear Previous Plans
Dive #1 Plan Result
Action
Depth
Stop
Run
Mix
pO2
EAD
NEXT DIVE
Text Report
DEBUG INFO TO DEVELOPER
Dive Plan Report
Copy
Close
Surface Interval
Set the time between dives. Tissues will off-gas during this interval.
▲
▼
days
▲
▼
hours
▲
▼
min
Start Next Dive
Cancel
Appearance
Language
English
Русский
Español
中文
हिन्दी
Français
Português
Deutsch
Italiano
한국어
Български
Norsk
日本語
Polski
Türkçe
Interface Style
Light Theme
Dark Theme
Model Settings
Circuit
OC
CCR
Deco Model
ZH-L16C GF
ZH-L16B GF
VPM-A
VPM-B
VPM-B/E
VPM-B/GFS
VPM-B/FBO
Conservatism
(0-5)
GF Lo
%
GF Hi
%
GFS Hi
%
O2 Narcotic
No
Yes
Cave Mode
No
Yes
Unit Settings
Depth Units
Meter
Feet
Water Type
Salt
Fresh
Altitude (m)
Acclimatized (m)
Gas Volume
Liter
CuFt
Pressure Units
BAR
PSI
Gauge Type
Simple
Digital
Temperature
°C
Descent / Ascent Rates
Descent Rate
m/min
Ascent Rate
m/min
Deco Ascent Rate
m/min
Surface Ascent Rate
m/min
Deco Stop Settings
Step Size
3
6
m
Last Stop (OC)
3
6
m
Last Stop (CCR)
3
6
9
m
Min Stop Time
1 min
30 sec
10 sec
1 sec
ppO2 Deco Swap
1.2
1.3
1.4
1.5
1.6
bar
ppO2 <=28% mix
1.2
1.3
1.4
1.5
1.6
bar
ppO2 28-45% mix
1.2
1.3
1.4
1.5
1.6
bar
ppO2 45-99% mix
1.2
1.3
1.4
1.5
1.6
bar
ppO2 Bottom Max
1.2
1.3
1.4
1.5
1.6
bar
O2 100% Max Depth
m
First Stop 30sec
Off
On
First Stop Double Step
Off
On
CCR Settings
Default Setpoint
bar
SP Units
BAR
ATA
RMV / Gas Planning
Bottom RMV
L/min
Deco RMV
L/min
CCR Dil Metabolic
L/min
Extended Stops
Extended Stops
Off
On
Add time to stop
Off
On
All mix changes
Off
On
O2 window effect
Off
On
Include extended stops with deco mix swaps
7..30 m
min
30 + m
min
Warning Thresholds
ppO2 High
bar
ppO2 Low
bar
CNS % above
%
OTU's above
IBCD N2
bar
IBCD He
bar
CCR diluent check
Check diluent ppO2 vs setpoint
Surface Interval / Multi-dive
Surface Interval
min (0 = off)
2-Week OTU
cumulative
Travel Gas O2%
%
Travel Gas He%
%
Reset Configuration
Load Debug Info
EAD, MOD, END
O2
%
He
%
Depth
m
ppO2 for MOD
0.50
0.55
0.60
0.65
0.70
0.75
0.80
0.85
0.90
0.95
1.00
1.05
1.10
1.15
1.20
1.25
1.30
1.35
1.40
1.45
1.50
1.55
1.60
1.65
1.70
1.75
1.80
bar
Setpoint (CCR)
bar
--
MOD
--
EAD
--
END
--
EADD
Best Mix
Depth
m
ppO2 Limit
0.50
0.55
0.60
0.65
0.70
0.75
0.80
0.85
0.90
0.95
1.00
1.05
1.10
1.15
1.20
1.25
1.30
1.35
1.40
1.45
1.50
1.55
1.60
1.65
1.70
1.75
1.80
bar
Trimix
No
Yes
EAD Depth
m
--
Best Mix
Mix Config
Pressure Units
bar
psi
Temperature Units
C
F
Temperature
0
5
10
15
20
25
30
35
Banked Gas
Air
32
Mix Nitrox
Old Pressure
bar
New Pressure
bar
Old O2
%
New O2
%
--
Add O2
--
Add Air
Mix Trimix
Old Pressure
bar
New Pressure
bar
Old O2
%
New O2
%
Old He
%
New He
%
Add First
He
O2
--
Add He
--
Add O2
--
Add Air
--
Test O2
Mix Topup
Old Pressure
bar
New Pressure
bar
Old O2
%
Old He
%
Top up with O2
%
Top up with He
%
--
Result
Mix Fill
Supply Start Pressure
bar
Supply Size
liters
Receive Size
liters
Receive Start Pressure
bar
Receive Add Pressure
bar
Equalize
Repeat
--
Supply Result
--
Receive Result
Density
O2
%
He
%
Depth
m
Mode
OC
SP
Setpoint
bar
Temperature
0C
20C
--
g/L
--
× Air
Add Bottom Level
Depth
m
Time (min)
O2 %
He %
Setpoint
bar
OC or SCR Leg:
OC
SCR
Save
Cancel
Add Deco Mix
O2 %
He %
Depth change override
Off
On
Depth
m
Save
Cancel
Add Bailout Mix
O2 %
He %
Bottom bailout mix
Depth change override
Off
On
Depth
m
Save
Cancel
Cancel
OK